Use cases
Application scenarios
265nm UVC LED cold disinfection with traceable monitoring for high-value recirculating loops. Each section covers the pain point, approach, and what can be verified.
Semiconductor · UPW
Microbial and biofilm risk in process water
Pain point: Trace microbes or pipe biofilm in UPW can hit yield; chemical dosing may add contamination and residual-management cost.
Approach: Apply 265nm UVC on critical paths for physical disinfection / biofilm suppression, with sensing and run logs for process audits.
What to verify: Mercury-free LEDs, adjustable dose, traceable data; final specs depend on flow and UVT assessment.
Read the scenario page →
AI data center · Liquid cooling
Biofilm in liquid-cooling CDUs and cold plates
Pain point: Biofilm lowers heat transfer, raises clog risk, and cuts available compute while raising O&M cost.
Approach: Deploy 265nm long-term biofilm suppression on coolant / recirculation paths to reduce harsh chemical dosing on piping and cold plates.
What to verify: Closed-loop flow and UV status monitoring; alerts and trends for DCIM integration.
Read the scenario page →
Aquaculture · Quarantine
Quarantine tank supply: per-tank logs, water between tanks
Pain point: Shared supply makes “which tank?” hard to answer; high asset value sits behind a small inlet.
Approach: One UVC 740 per tank/group with dose/UVT filed per tank—no survival-rate promises.
What to verify: Separate supply and timestamped per-tank logs; PoC compares water-quality metrics, not survival rates.
Read the scenario page →
Hospital · ST108 critical water
We keep the loop honest in between
Pain point: Under ST108, critical water gets daily conductivity checks—but bacteria and endotoxin often only monthly. Equipment isn't continuous evidence; the days between tests are where loops drift.
Approach: Hyper Flux™ UVC 740 runs continuously on the loop—delivered dose and UVT logged. Monthly testing and sanitization stay; the unit steps aside on bypass during sanitization. Not point-of-use.
What to verify: Does not replace monthly testing or sanitization; this page describes technical direction only—validate per site rules.
Facilities · Cooling towers
Biosafety for public and commercial cooling water
Pain point: Cooling towers are high-risk for Legionella; incidents cost health, downtime, and reputation.
Approach: Use 265nm as a microbial-control option in recirculating water, with IoT records for O&M evidence.
What to verify: Must sit inside a broader water-management design—not a single device replacing every control.
Want to evaluate your loop?
Share design flow, pipe size, water-quality targets, and system drawings. Or start with the FAQ.